| Rack Height | 2U |
| Specifications | |
| Controller Performance | Up to 12GB/s read throughput, 10GB/s write throughput, 725K IOPS (Random Read) |
| Advanced Software Features | Auto-tiering, Snapshots, Asynchronous Replication |
| Base Array Software Features | Virtual pools, Thin provisioning, ADAPT, SSD read cache, Encryption |
| High-Availability Features | Redundant hot-swap controllers, Redundant hot-swap drives, fans, power, Dual power cords, Hot standby spare, Automatic failover, Multi-path support |
| Device (Drive) Support | SAS HDD, NL-SAS HDD, SAS SSD (2.5 or 3.5 Form Factors) |
| Data Protection | ADAPT and RAID levels supported: 0, 1, 5, 6, 10 |
| Self-Healing Technology | Autonomous Drive Regeneration (ADR) |
| System Maximum Expansion | 2U24 Arrays, Up to 24 drives per enclosure, 10 enclosures maximum including the master, totaling 240 Drives |
| Hosts | |
| External Ports | 4 per Controller, 8 per System |
| Fibre Channel Models | Host speed: 32/16 Gb/s Fibre Channel, Interface type: SFP+/SFP28 |
| iSCSI Models | Host speed: 10Gb/s, 25Gb/s iSCSI, Interface type: SFP+/SFP28 |
| Ethernet | 10GBASE-T (auto-negotiation to 1Gb) |
| SAS Models | Host speed: 12Gb/s, 6Gb/s SAS, Interface type: HD Mini-SAS |
| System Configuration | |
| System Memory | 48GB per system Expandable up to 256GB per Controller |
| Volumes per System | 1024 |
| Cache | Mirrored cache, Supercapacitor cache backup, Cache backup to flash – non-volatile |
| Management | |
| Interface Types | 10/100/1000 Ethernet, Micro USB |
| Protocols Supported | SNMP, SSL, SSH, SMTP, HTTP(S), REDFISH |
| Management Consoles | Web GUI, CLI |
| Management Software | Exatron -Seagate Systems storage management console, Remote diagnostics, Nondisruptive updates, Volume expansion |
| Power Requirements—AC Input | |
| Input Power | 200VAC - 240VAC, 50Hz-60Hz |
| Max Power Output per PSU | 750 Watts x 2 (80 PLUS Platinum) |
| Environmental/Temperature Ranges | |
| Operating/Nonoperating Temperature | ASHRAE A2, 5°C to 35°C (41°F to 95°F), derate 1°C/300m above 900m, 20°C/hr max rate of change / –40°C to 70°C (–40°F to 158°F) |
| Operating/Nonoperating Humidity | ,-12°C DP and 8% RH to 21°C DP and 80% RH, max DP 21°C / 5% to 100% nonconcern |
| Operating/Nonoperating Shock | 3 Gs, 11ms, half sine pulses / 15 Gs, 7ms, half sine pulses |
| Operating/Nonoperating Vibration | 0.18 Gs rms 6Hz to 500Hz random / 0.5 (Z-axis) and 0.25 (X&Y-axis) Gs rms 6Hz to 200Hz random |